Case Study: Reduction of Minimum Allowable Metal Temperature of a Refrigerated Vessel

At a recent technical conference, an ammonia producer learned about the benefits of fitness-for-service. Inspired by the example discussed during a technical presentation, the producer identified a vessel at one facility that had recently been listed for replacement due to insufficiently low minimum temperature ratings.

The vessel, a NH3 refrigerated gas chiller, was identified as having a minimum temperature rating of -10°F, higher than the low gas temperature. Using all available documentation, a quick Level 2 Brittle Fracture assessment of the vessel determined that it could be operated at a minimum metal temperature of -35°F. The producer was able to keep the vessel in service and spend the planned replacement funds on other reliability projects.

For inquires or to reply to this email, please email MarketingQIG@QuestIntegrity.com

Quiz Question

What is the lowest minimum allowable metal temperature (MAT) allowed by a brittle fracture assessment?

(Scroll down for answer)

 

Quiz Answer:

-155° F